Table of Contents
Overview of Vacuum Cast Coil Dry Type Transformers
Vacuum cast coil dry type transformers are an innovative solution that combines advanced technology with reliable performance. These transformers are designed for environments where traditional oil-filled transformers may not be suitable due to safety and environmental concerns. The vacuum casting process ensures that the coils are completely encapsulated in a resin, providing excellent insulation and protection against moisture, dust, and other contaminants.
One of the key advantages of vacuum cast coil transformers is their compact size, making them ideal for urban installations where space is limited. Their dry type construction eliminates the risk of oil leaks, which is a significant concern for many industries. Additionally, these transformers offer high efficiency and low maintenance requirements, contributing to lower operational costs over their lifespan.
Compliance with IEC 60076 Standard
The IEC 60076 standard is a crucial benchmark for the design and performance of power transformers, including vacuum cast coil dry type transformers. This standard outlines the necessary requirements for safety, testing, and performance, ensuring that manufacturers produce reliable and efficient products. By adhering to IEC 60076, manufacturers demonstrate their commitment to quality and reliability in transformer production.
Compliance with this standard not only enhances product credibility but also assures customers that they are investing in safe and effective electrical equipment. Manufacturers must conduct rigorous testing, including temperature rise tests and short-circuit tests, to meet the IEC 60076 specifications. This adherence helps reduce the risk of failures in the field, promoting long-term operational stability.
Leading Manufacturing Companies in the Industry
Several companies have established themselves as leaders in the manufacturing of vacuum cast coil dry type transformers. These manufacturers leverage cutting-edge technology and expertise to produce transformers that meet international standards and customer requirements. Their commitment to quality assurance and continuous improvement sets them apart in a competitive market.
SC(B)10
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SC10-30
30
6,6.3,6.6,10,11/0.4
190
710
2.4
4.0
SC10-50
50
6,6.3,6.6,10,11/0.4
270
1000
2.4
4.0
SC10-80
80
6,6.3,6.6,10,11/0.4
370
1380
1.8
4.0
SC10-100
100
6,6.3,6.6,10,11/0.4
400
1570
1.8
4.0
SC10-125
125
6,6.3,6.6,10,11/0.4
470
1850
1.6
4.0
SCB10-160
160
6,6.3,6.6,10,11/0.4
550
2130
1.6
4.0
SCB10-200
200
6,6.3,6.6,10,11/0.4
630
2530
1.4
4.0
SCB10-250
250
6,6.3,6.6,10,11/0.4
720
2760
1.4
4.0
SCB10-315
315
6,6.3,6.6,10,11/0.4
880
3470
1.2
4.0
SCB10-400
400
6,6.3,6.6,10,11/0.4
980
3990
1.2
4.0
SCB10-500
500
6,6.3,6.6,10,11/0.4
1160
4880
1.2
4.0
SCB10-630
630
6,6.3,6.6,10,11/0.4
1350
5880
1.0
4.0
SCB10-630
630
6,6.3,6.6,10,11/0.4
1300
5960
1.0
6.0
SCB10-800
800
6,6.3,6.6,10,11/0.4
1520
6960
1.0
6.0
SCB10-1000
1000
6,6.3,6.6,10,11/0.4
1770
8130
1.0
6.0
SCB10-1250
1250
6,6.3,6.6,10,11/0.4
2090
9690
1.0
6.0
SCB10-1600
1600
6,6.3,6.6,10,11/0.4
2450
11730
1.0
6.0
SCB10-2000
2000
6,6.3,6.6,10,11/0.4
3050
14450
0.8
6.0
SCB10-2500
2500
6,6.3,6.6,10,11/0.4
3600
17170
0.8
6.0